{"id":2281,"date":"2026-08-12T00:00:00","date_gmt":"2026-08-12T00:00:00","guid":{"rendered":"https:\/\/onpowbutton.com\/news\/triple-pole-push-button-switch-layout-guide\/"},"modified":"2026-08-13T06:01:00","modified_gmt":"2026-08-13T06:01:00","slug":"triple-pole-push-button-switch-layout-guide","status":"publish","type":"post","link":"https:\/\/onpowbutton.com\/ru\/news\/triple-pole-push-button-switch-layout-guide\/","title":{"rendered":"How to Specify a Triple Pole Push Button Switch in a Control Panel"},"content":{"rendered":"<div class=\"b2b-article\">\n<p style=\"margin:0 0 16px;line-height:1.7\"><strong>For a triple-pole push button switch, three separate contact paths sit under one operator, but that arrangement is not automatically a three-phase power switch.<\/strong> Start with the schematic: define each pole\u2019s NO\/NC state, terminal labels, actuation mode, and circuit duty before choosing a panel body.<\/p>\n<figure style=\"margin:26px 0;text-align:center\"><img decoding=\"async\" style=\"max-width:640px;width:100%;height:auto;display:block;margin:0 auto;border-radius:8px\" src=\"https:\/\/onpowbutton.com\/wp-content\/uploads\/2026\/08\/onpow-gq22-series.webp\" alt=\"ONPOW GQ22 metal push button series for control panel specification\"><\/figure>\n<nav class=\"b2b-toc\" style=\"background:#f5f8fa;padding:16px 20px;border-radius:8px;margin:0 0 24px\">\n<h2 id=\"contents\" style=\"margin:42px 0 14px;scroll-margin-top:96px\">Contents<\/h2>\n<ul style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\"><a style=\"color:#27649a;text-decoration:underline\" href=\"#part-1-what-triple-pole-means-in-a-push-button-circuit\">Part 1. What triple-pole means in a push-button circuit<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a style=\"color:#27649a;text-decoration:underline\" href=\"#part-2-how-to-map-three-poles-before-wiring\">Part 2. How to map three poles before wiring<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a style=\"color:#27649a;text-decoration:underline\" href=\"#part-3-panel-and-actuator-checks-that-affect-the-layout\">Part 3. Panel and actuator checks that affect the layout<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a style=\"color:#27649a;text-decoration:underline\" href=\"#part-4-where-the-control-circuit-boundary-stops\">Part 4. Where the control-circuit boundary stops<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a style=\"color:#27649a;text-decoration:underline\" href=\"#part-5-how-to-use-the-onpow-gq22-family-as-a-starting-path\">Part 5. How to use the ONPOW GQ22 family as a starting path<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a style=\"color:#27649a;text-decoration:underline\" href=\"#part-6-what-to-send-in-the-rfq-and-when-to-stop\">Part 6. What to send in the RFQ and when to stop<\/a><\/li>\n<\/ul>\n<\/nav>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"part-1-what-triple-pole-means-in-a-push-button-circuit\">Part 1. What triple-pole means in a push-button circuit<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">A pole is a separate contact path. A triple-pole operator therefore gives the designer three paths that may be assigned to three NO contacts, three NC contacts, or a mixed arrangement when the selected model supports it.<\/p>\n<table style=\"width:100%;border-collapse:collapse\">\n<thead>\n<tr>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Specification term<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">What it tells the panel designer<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">What it does not tell you<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Pole<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Number of separate contact paths<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">The voltage or load duty<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Throw<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Whether a path changes between contacts<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">The physical terminal location<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">NO \/ NC<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">State before and during actuation<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Whether all poles share the same rating<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Momentary \/ maintained<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">How long the state is held<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Whether a safety circuit is validated<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"margin:0 0 16px;line-height:1.7\">The actuator can move one mechanism while the electrical design treats the three poles as separate circuits. That makes the contact schedule more important than the marketing label.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"part-2-how-to-map-three-poles-before-wiring\">Part 2. How to map three poles before wiring<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Start with a pole-by-pole terminal schedule rather than a single \u201cthree-pole\u201d note. Give every contact path an identifier such as P1, P2, and P3, then record its normal state, destination, wire reference, and test condition.<\/p>\n<table style=\"width:100%;border-collapse:collapse\">\n<thead>\n<tr>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Pole<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Normal state<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Actuated state<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Destination<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">RFQ note<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">P1<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">NO or NC<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Opposite state<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Command input 1<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Record terminal numbers<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">P2<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">NO or NC<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Opposite state<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Indicator or interlock input<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Confirm shared reference<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">P3<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">NO or NC<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Opposite state<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">PLC or relay input<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Confirm isolation need<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"margin:0 0 16px;line-height:1.7\">This table prevents a common error: assuming that a three-pole operator has three identical contact blocks when the drawing actually needs a mixed NO\/NC arrangement. It also gives purchasing a checkable terminal list.<\/p>\n<blockquote>\n<p style=\"margin:0 0 16px;line-height:1.7\"><strong>Tip:<\/strong> Compare the wiring schedule with the manufacturer drawing and the <a style=\"color:#27649a;text-decoration:underline\" href=\"https:\/\/onpowbutton.com\/ru\/news\/normally-open-switch-vs-normally-closed-switch\/\">NO versus NC guide<\/a> before releasing a panel BOM. IEC device terminology defines scope, but the selected model drawing defines the terminal map (<a style=\"color:#27649a;text-decoration:underline\" href=\"https:\/\/webstore.iec.ch\/en\/publication\/2603\" target=\"_blank\" rel=\"noopener\">IEC 60947-5-1<\/a>).<\/p>\n<\/blockquote>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"part-3-panel-and-actuator-checks-that-affect-the-layout\">Part 3. Panel and actuator checks that affect the layout<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Contact topology does not remove mechanical constraints. Verify the panel cutout, body depth, terminal orientation, nut or clip engagement, and the clearance needed to bend wires without loading the terminals.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Use the <a style=\"color:#27649a;text-decoration:underline\" href=\"https:\/\/onpowbutton.com\/ru\/news\/push-button-control-panel-layout-guide\/\">push-button control-panel layout guide<\/a> for the broader drilling sequence, then add these triple-pole checks:<\/p>\n<ul style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\">reserve space for three terminal paths and their labels;<\/li>\n<li style=\"margin:0 0 8px\">show the rear body and wire bend envelope on the drawing;<\/li>\n<li style=\"margin:0 0 8px\">test the operator with the intended glove and access conditions;<\/li>\n<li style=\"margin:0 0 8px\">separate signal wiring from higher-energy conductors where the cabinet design requires it;<\/li>\n<li style=\"margin:0 0 8px\">keep the pole identifiers visible in the schematic and inspection record.<\/li>\n<\/ul>\n<figure style=\"margin:26px 0;text-align:center\"><img decoding=\"async\" style=\"max-width:640px;width:100%;height:auto;display:block;margin:0 auto;border-radius:8px\" src=\"https:\/\/onpowbutton.com\/wp-content\/uploads\/2026\/08\/01-metal-push-button-box-overview.webp\" alt=\"Metal push button panel layout and rear access planning\"><\/figure>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"part-4-where-the-control-circuit-boundary-stops\">Part 4. Where the control-circuit boundary stops<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Triple-pole describes contact paths, not a blanket permission to switch a motor, heater, or three-phase branch. The load, utilization category, inrush, isolation method, and local safety design still control the selection.<\/p>\n<table style=\"width:100%;border-collapse:collapse\">\n<thead>\n<tr>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Application question<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Why it matters<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Is this a PLC, relay, lamp, or contactor command?<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">A control input is different from a power path.<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">What are the steady and transient currents?<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">A catalogue current field may not cover the actual duty.<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Does the function affect safety?<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">An emergency-stop or interlock function needs its own validated architecture.<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Are the poles electrically independent?<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Shared references can change the wiring and test plan.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<blockquote>\n<p style=\"margin:0 0 16px;line-height:1.7\"><strong>Important:<\/strong> Do not use a triple-pole button as proof that a three-phase load may be switched directly. Confirm the model\u2019s rated duty and use a contactor or safety architecture when the circuit requires one (<a style=\"color:#27649a;text-decoration:underline\" href=\"https:\/\/webstore.iec.ch\/en\/publication\/2603\" target=\"_blank\" rel=\"noopener\">IEC 60947-5-1 control circuit devices<\/a>).<\/p>\n<\/blockquote>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"part-5-how-to-use-the-onpow-gq22-family-as-a-starting-path\">Part 5. How to use the ONPOW GQ22 family as a starting path<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">\u0417\u0435\u043c\u043b\u044f <a style=\"color:#27649a;text-decoration:underline\" href=\"https:\/\/onpowbutton.com\/ru\/anti-vandal-waterproof-push-button\/\">ONPOW GQ22 metal push button category<\/a> is a sensible starting route when the project needs a metal panel operator and the buyer can confirm the required contact arrangement on a specific model page or drawing. The category page is a routing point, not a substitute for a model-level electrical schedule.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Before selecting a GQ22 SKU, match:<\/p>\n<ol style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\">required pole and NO\/NC arrangement;<\/li>\n<li style=\"margin:0 0 8px\">momentary or maintained operation;<\/li>\n<li style=\"margin:0 0 8px\">panel cutout and thickness;<\/li>\n<li style=\"margin:0 0 8px\">terminal style and rear clearance;<\/li>\n<li style=\"margin:0 0 8px\">contact duty for each of the three paths;<\/li>\n<li style=\"margin:0 0 8px\">front environmental requirement and documentation.<\/li>\n<\/ol>\n<p style=\"margin:0 0 16px;line-height:1.7\">For broader metal construction options, review the <a style=\"color:#27649a;text-decoration:underline\" href=\"https:\/\/onpowbutton.com\/ru\/metal-push-button-switch\/\">metal push button switch line<\/a>. If the drawing cannot prove the three-pole arrangement, stop at the family-review stage and ask engineering for the exact model evidence.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"part-6-what-to-send-in-the-rfq-and-when-to-stop\">Part 6. What to send in the RFQ and when to stop<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Send the following with the quote request through <a style=\"color:#27649a;text-decoration:underline\" href=\"https:\/\/onpowbutton.com\/ru\/contact-us\/\">\u0421\u0432\u044f\u0436\u0438\u0442\u0435\u0441\u044c \u0441 \u043d\u0430\u043c\u0438<\/a>:<\/p>\n<ul style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\">schematic showing P1, P2, and P3;<\/li>\n<li style=\"margin:0 0 8px\">NO\/NC state for every pole;<\/li>\n<li style=\"margin:0 0 8px\">momentary or maintained requirement;<\/li>\n<li style=\"margin:0 0 8px\">panel cutout, thickness, and rear clearance drawing;<\/li>\n<li style=\"margin:0 0 8px\">terminal and wire-entry preference;<\/li>\n<li style=\"margin:0 0 8px\">steady, transient, and load type for each circuit;<\/li>\n<li style=\"margin:0 0 8px\">environment, front protection target, and documentation needs;<\/li>\n<li style=\"margin:0 0 8px\">quantity, sample requirement, and revision-controlled drawing.<\/li>\n<\/ul>\n<p style=\"margin:0 0 16px;line-height:1.7\">Stop and request engineering confirmation if the design assumes direct motor switching, a safety function, an unlisted pole arrangement, or a rating copied from a different model.<\/p>\n<figure style=\"margin:26px 0;text-align:center\"><img decoding=\"async\" style=\"max-width:640px;width:100%;height:auto;display:block;margin:0 auto;border-radius:8px\" src=\"https:\/\/onpowbutton.com\/wp-content\/uploads\/2026\/07\/LAS0-push-button-switch.webp\" alt=\"ONPOW metal push button operator family for panel selection\"><\/figure>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"faqs\">\u0427\u0430\u0441\u0442\u043e \u0437\u0430\u0434\u0430\u0432\u0430\u0435\u043c\u044b\u0435 \u0432\u043e\u043f\u0440\u043e\u0441\u044b<\/h2>\n<h3 style=\"margin:28px 0 12px\">What does triple pole mean on a push button switch?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">It means the operator controls three separate contact paths. The exact NO\/NC arrangement and terminal numbering remain model-specific.<\/p>\n<h3 style=\"margin:28px 0 12px\">Is a triple-pole button the same as a three-phase power switch?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">No. Three poles describe contact paths; they do not prove that the button is rated for a three-phase load or motor duty.<\/p>\n<h3 style=\"margin:28px 0 12px\">How many terminals should an RFQ list?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">List the terminal numbers for each pole from the chosen model drawing. Do not infer the terminal count from the phrase \u201ctriple pole\u201d alone.<\/p>\n<h3 style=\"margin:28px 0 12px\">Does momentary versus maintained change all poles together?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">It depends on the selected mechanism. State the required actuation mode and verify the model drawing before ordering.<\/p>\n<h3 style=\"margin:28px 0 12px\">How much rear clearance is needed?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Enough for the body, terminal orientation, wire bend radius, and service access shown on the model drawing. A panel thickness alone is not a rear-clearance specification.<\/p>\n<h3 style=\"margin:28px 0 12px\">When is a contactor still required?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Use a contactor or other controlled architecture when the downstream load, inrush, isolation, or safety design exceeds the push-button contact duty.<\/p>\n<h3 style=\"margin:28px 0 12px\">What should I send with a triple-pole quote request?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Send the schematic, pole states, model preference, panel drawing, circuit duty, environment, quantity, and documentation requirements.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"references\">References<\/h2>\n<ul style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\"><a style=\"color:#27649a;text-decoration:underline\" href=\"https:\/\/webstore.iec.ch\/en\/publication\/2603\" target=\"_blank\" rel=\"noopener\">IEC 60947-5-1 control circuit devices<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a style=\"color:#27649a;text-decoration:underline\" href=\"https:\/\/www.eaton.com\/us\/en-us\/catalog\/controls-drives-automation-sensors\/pushbuttons-pilot-devices.html\" target=\"_blank\" rel=\"noopener\">Eaton pushbuttons and pilot devices<\/a><\/li>\n<\/ul>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>For a triple-pole push button switch, three separate contact paths sit under one operator, but that arrangement is not automatically a three-phase power switch. Start with the schematic: define each pole\u2019s NO\/NC state, terminal labels, actuation mode, and circuit duty before choosing a panel body. Contents Part 1. What triple-pole means in a push-button circuit [&hellip;]<\/p>\n","protected":false},"author":5,"featured_media":2267,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_uag_custom_page_level_css":"","footnotes":""},"categories":[1],"tags":[],"class_list":["post-2281","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"uagb_featured_image_src":{"full":["https:\/\/onpowbutton.com\/wp-content\/uploads\/2026\/08\/onpow-gq22-series.webp",800,500,false],"thumbnail":["https:\/\/onpowbutton.com\/wp-content\/uploads\/2026\/08\/onpow-gq22-series-150x150.webp",150,150,true],"medium":["https:\/\/onpowbutton.com\/wp-content\/uploads\/2026\/08\/onpow-gq22-series-300x188.webp",300,188,true],"medium_large":["https:\/\/onpowbutton.com\/wp-content\/uploads\/2026\/08\/onpow-gq22-series-768x480.webp",768,480,true],"large":["https:\/\/onpowbutton.com\/wp-content\/uploads\/2026\/08\/onpow-gq22-series.webp",800,500,false],"1536x1536":["https:\/\/onpowbutton.com\/wp-content\/uploads\/2026\/08\/onpow-gq22-series.webp",800,500,false],"2048x2048":["https:\/\/onpowbutton.com\/wp-content\/uploads\/2026\/08\/onpow-gq22-series.webp",800,500,false],"trp-custom-language-flag":["https:\/\/onpowbutton.com\/wp-content\/uploads\/2026\/08\/onpow-gq22-series-18x12.webp",18,12,true]},"uagb_author_info":{"display_name":"Relife","author_link":"https:\/\/onpowbutton.com\/ru\/author\/relife\/"},"uagb_comment_info":0,"uagb_excerpt":"For a triple-pole push button switch, three separate contact paths sit under one operator, but that arrangement is not automatically a three-phase power switch. Start with the schematic: define each pole\u2019s NO\/NC state, terminal labels, actuation mode, and circuit duty before choosing a panel body. Contents Part 1. What triple-pole means in a push-button circuit&hellip;","_links":{"self":[{"href":"https:\/\/onpowbutton.com\/ru\/wp-json\/wp\/v2\/posts\/2281","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/onpowbutton.com\/ru\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/onpowbutton.com\/ru\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/onpowbutton.com\/ru\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/onpowbutton.com\/ru\/wp-json\/wp\/v2\/comments?post=2281"}],"version-history":[{"count":2,"href":"https:\/\/onpowbutton.com\/ru\/wp-json\/wp\/v2\/posts\/2281\/revisions"}],"predecessor-version":[{"id":2284,"href":"https:\/\/onpowbutton.com\/ru\/wp-json\/wp\/v2\/posts\/2281\/revisions\/2284"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/onpowbutton.com\/ru\/wp-json\/wp\/v2\/media\/2267"}],"wp:attachment":[{"href":"https:\/\/onpowbutton.com\/ru\/wp-json\/wp\/v2\/media?parent=2281"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/onpowbutton.com\/ru\/wp-json\/wp\/v2\/categories?post=2281"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/onpowbutton.com\/ru\/wp-json\/wp\/v2\/tags?post=2281"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}